Brand Name: Pullner
Model Number: PTFE
Place of Origin: China
High Quality Pharmaceutical Filters Sterile PTFE Micron Pleated Cartridge Filters
General Description
Hydrophobic Polytetrafluoroethylene filter, the filter medium is hydrophobic Polytetrafluoroethylene microporous membrane: strong hydrophobicity, high rejection, excellent chemical resistance and thermal stability, good strength, positive resistance forward and reverse pressure shock.
Applications
Chemical industry: filtration of organic solvents, various alcohols, chemical reagents, etc.
Gas filtration: sterilization filtration of compressed air, nitrogen, carbon dioxide, etc.
Filtration of sterile tank respirators, air fermenters, etc.
Features
1. Excellent performance of high temperature-resistance, repeat steam ability in situ;
2. Hydrophobic membrane with high flow;
3. Low pressure drop, high flow rate, long service life;
4. 100% integrity tested;
5. Non fiber-releasing;
6. FDA compliance material;
Dimensions
Outer diameter |
2.7" (69mm) |
Length |
10", 20", 30", 40" |
Material of Construction
Filter Medium |
PTFE |
Support/Drainage |
PP |
Center core/Outer Cage/End Caps |
PP |
Seals Material |
NBR, Silicone, EPDM, Viton, Teflon |
Filter Performance
Removal rating |
For Gas: 0.04um, 0.022um |
For Liquid: 0.1um, 0.22um, 0.45um, 0.65um |
|
Max. operating temperature |
80℃ 0.17Mpa |
Max. tolerance temperature |
140℃ 0.27Mpa |
Max. operating differential pressure |
4.2 Bar @ 25℃ |
Max. operating differential pressure (Reverse direction) |
2.0 Bar @ 25℃ |
Max. temperature sterilization |
121℃, 30 minutes |