Brand Name: CHZIRI
Model Number: ZJR2, ZJR2 Series
Place of Origin: Zhejiang, China (Mainland)
ZJR2 Series AC Motor Soft Starter 3 Phase 380V/415V/440V/480V
Power Range: 5.5kW, 7.5kW, 11kW, 15kW, 18.5kW, 22kW, 30kW, 37kW, 45kW, 55kW, 75kW, 90kW, 110kW, 132kW, 160kW, 185kW, 200kW, 250kW, 280kW, 315kW, 400kW, 450kW, 500kW, 600kW
MAIN FEATURE:
1. 16 SCM control, intelligent all-digital display;
2. Can be put into practice a soft starter control multiple motors;
3. Four starting modes: Start voltage, current limiting starter, starting torque, torque +sudden danced dynamic;
4. Free and soft shutdown, downtime 0 to 60 seconds can be arbitrary choice;
5. With the flow, over loading, lack phase, instantaneous stop, and other malfunction protection;
6. Easy installation, simple operation, strong function and reasonable prices;
APPLICATION:
ZJR-2 Soft Starter |
Main Technic Data |
||
Input Power Supply |
Input Voltage |
Three-phase 380V-15% ~415+10% |
|
Frequency |
50/60Hz |
||
Adaptive Motor |
Squirrel-cage three-phase asynchronous motor |
||
Starting Times |
It is recommended not to exceed 20 times per hour. |
||
Control Mode |
1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. |
||
Start Mode |
1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. |
||
Stop Mode |
1) Soft stop; 2) Free stop. |
||
Protective Function |
Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protectionfor fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. |
||
Ambient |
Place to be used |
Indoor location with good ventilation free from corrosive gas and conductive dust. |
|
Altitude |
Below 3000M. It have to rise the rate power when the altitude is more than 3000M. |
||
Ambient |
|
||
Ambient Humidity |
≤90%RH without dew condensation. |
||
Vibration |
<0.5G |
||
Structure |
Protection Class |
IP20 |
|
Cooling Pattern |
Natural wind cooling. |