Brand Name: OEM
Model Number: ZJR2-
Place of Origin: Zhejiang, China (Mainland)
Soft Starter Feature | ||
|
3. Starting modes: Current limiting starter, Voltage ramp start , Kick start +current-limiting start, kick start +voltage ramp start . Current ramp start . Voltage current-limiting double closed –loop start .
4. free stop and soft stop , The stop time from 0 to 60 seconds can be arbitrary choosed .
5. Over current , Overload , Open phase, instantaneous stop and other fault protection .
with the flow, over loading, lack phase, instantaneous stop, and other malfunction protection;
6. Easy installation, simple operation, strong function and reasonable prices;
Product Description | ||
|
|
Product Name | 3 phase motor soft starter for motor control, water pump soft motor starter, Low voltage soft starter for air compressor |
Description | 1. ZJR2 series soft starter can work with three-phase, AC squirrel cage induction asynchronous motor, The voltage is 320V~460V, 50HZ/60HZ and the current is 1200A and below . 2. ZJR2 series soft starter are in the process of motor starting and running a perfect protection function, adopted the closed loop control, greatly improving the stationarity of soft starting torque of the motor. 3. The soft starter is a device type .It’s necessary to add breakers (short-circuit protection ) and AC contactor (Bypass) inside the cabinet . together with switches are made up of electric motor control circuit . |
OEM | Yes |
Certificate | CE, ISO |
Warranty Time | 1 Year |
Payment Terms | T/T,L/C, Western Union, Cash |
Delivery Time | within 7 days |
Shipping Methods | DHL / EMS / UPS / FedEx / BY sea
(According to customer's requirement) |
Need Professional Recommendation? |
Technical Indications | ||
Item |
Item Description |
||
Input Power Supply |
Input Voltage |
Three Phase 380V-15% ~ 415+10% |
|
Frequency |
50/60Hz |
||
Adaptive Motor |
Squirrel-cage three-phase asynchronous motor |
||
Starting Times |
It is recommended not to exceed 20 times per hour. |
||
Control Mode |
1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. |
||
Start Mode |
1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. |
||
Stop Mode |
1) Soft stop; 2) Free stop. |
||
Protective Function |
1) Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. |
||
Ambient |
Place to be used |
Indoor location with good ventilation free from corrosive gas and conductive dust. |
|
Altitude |
Below 3000M. It have to rise the rate power when the altitude is more than 3000M. |
||
Ambient Temperature |
-30~+55℃ |
||
Ambient Humidity |
≤90%RH without dew condensation. |
||
Vibration |
<0.5G |
||
Structure |
Protection Class |
IP20 |
|
Cooling Pattern |
Natural wind cooling. |
Wiring For Starter | ||
|