Brand Name: hiseer
Model Number: AW10/B-DNNHE
Place of Origin: China (Mainland)
10kw Air source heating cooling chillers are well designed for high efficiency running, brings quiet consistent comfort to thousands of people around the world.
10kw Air source heating cooling chillers removes heat from the water via a vapor-compression refrigeration cycle. In air conditioning systems, chilled water is distributed to heat exchangers, or coils, in air handling units or other types of terminal devices which cool the air in their respective space, and then the water is re-circulated back to the chiller to be cooled again. These cooling coils transfer sensible heat and latent heat from the air to the chilled water, thus cooling and usually dehumidifying the air stream.
Built-in differential pressure flow switch protect the unit from insufficient water flow rate.
Hitachi scroll R410A compressor
With Germany’s Siemens controller, the control system is intelligent ,stable and durable to assure safe running .
SWEP/GEA Brazed Plate Heat Exchanger (BPHE) is one of the most efficient ways to transfer heat from refrigerant to water. A BPHE consists of corrugated plates combined to create complex channels through which refrigerant and water can be distributed.
Technical data:
Air cooled chiller | AW10/B | |||
Heat output/Power consumption at 7/35°C | kW | 11.0/2.7 | ||
COP at 7/35°C | 4.07 | |||
Heat output/Power consumption at 7/45°C | kW | 10.5/3.3 | ||
COP at 7/45°C | 3.18 | |||
Heat output/Power consumption at 7/55°C | kW | 10.2/4.1 | ||
COP at 7/55°C | 2.49 | |||
Heat output/Power consumption at 2/35°C | kW | 9.5/2.6 | ||
COP at 2/35°C | 3.65 | |||
Heat output/Power consumption at 2/45°C | kW | 9.2/3.4 | ||
COP at 2/45°C | 2.71 | |||
Heat output/Power consumption at -7/35°C | kW | 7.2/2.3 | ||
COP at -7/35°C | 3.13 | |||
Heat output/Power consumption at -7/45°C | kW | 7.1/3.4 | ||
COP at -7/45°C | 2.09 | |||
Cool output/Power consumption at 35/7°C | KW | 9.5/3.3 | ||
COP at 35/7°C | 2.88 | |||
Starting current | A | 46 | ||
Soft-start relay | ||||
Power | 380-415V/3PH/50Hz | |||
Compressor | HITACHI scroll | |||
Condenser | Brazed plate heat exchanger | |||
Nominal flow heating medium | m3/h | 1.87 | ||
Internal pressure drop at nominal flow | kPa | 23 | ||
Air flow | m3/h | 3000 | ||
Nominal output fan | W | 220 | ||
Max outgoing heating medium temperature | °C | 55°C | ||
Refrigerant R410A filling weight | kg | 3.8 | ||
Dimensions(HxWxD) | mm | 1050x1050x450 | ||
Pipe connector | DN25 | |||
Weight | kg | 125 | ||
Operating ambient temp. range | °C | Heating -10~35 | ||
Cooling 10~45 | ||||
DHW -10~43 | ||||
The above data is tested by EN14511. 7/35°C means air temp. 7°C,outlet water temp. 35°C |
typical installation diagram: