Brand Name: TEREN
Model Number: DPT/DPTL
Place of Origin: Guangdong, China (Mainland)
Diff. pressure transmitter with LCD display as below
Diff. pressure transmitter without LCD display as below
Applications & Features
Specifications
Medium: non-combustible, non-corrosive air, insensitive to moisture, dust, condensation and oil
Working Temp.: -20~70°C
Medium Temp.: 0-60°C
Compensated Temp.: 0-50°C
Working pressure: overload 10xFS, burst 15xFS
Accuracy: up to ±1.0%FS, see accuracy table
Long term stability: ±0.5%FS /Year
Temp. Drift: < 0.05%FS/°C
Response time: 0.5-30s, can be set by button keys
Process Connection: 5mm ID tubing
Display: 5 digit LCD, with unit indication, field upgradable
Output: 0~10V, 4~20mA (2 wires), RS485 selectable
Output Load: ≤500Ω (current), ≥2KΩ (voltage)
Power Supply: 15~28V AC/15~36VDC
Unit select: by keys
Zero set: easy to reset by external key
Materials: ABS (housing) & PC (cover)
Protection: IP54
Approval: CE
Models
Model |
DPT |
DP transmitter |
|||
DPTL |
Economical DP transmitter |
||||
Range |
See table |
Ranges selectio |
|||
Output | 1 2 8 |
|
0-10V 4-20mA (2 wires) RS485 |
||
Display |
|
0 1 |
N/A LCD |
Accessory:
1. Flush mount panel
Model: DPT-A
316 SS panel, for flush mount, no duct and easy toclean.
Dimensions:103(W)×91(H)×1.2(D)mm
2. Field upgradeable LCD Display
Model: DPT-LCD-1/DPT-LCD-5
Each package has the LCD module and the film for the cover 1 set (-1) or 5 sets (-5)
DPT Measuring ranges
Code | UNIT & Ranges |
Accuracy (%FS) |
|||||
Pa | Pa | KPa | In W.C | mm W.C | mbar | DPT |
|
1 | 0-60/125 | 60.00 | 0.060 | 0.250 | 6.000 | 0.600 | 1% |
125.0 | 0.125 | 0.500 | 12.00 | 1.250 | 1% | ||
3 | 0-250/500/1000 | 250.0 | 0.250 | 1.000 | 25.00 | 2.500 | 1% |
500.0 |
0.500 | 2.000 | 50.00 | 5.000 | 1% | ||
1000 | 1.000 | 4.000 | 100.0 | 10.00 | 1% | ||
6 | 0-2000 | 2000 | 2.000 | 8.000 | 200.0 | 20.00 | 1% |
7 | 0-5000 | 5000 | 5.000 | 20.00 | 500.0 | 50.00 | 1% |
8 | 0-10000 | 10000 | 10.00 | 40.00 | 1000 | 100.0 | 1% |
Note: 1. Code 1 and 3 have multiple ranges which could be jumper selected.
2. Set the 5 engineering units by button keys and the related LCD indicator will be on.
3. For zero center models, add “Z” at the end of the model. For example, DPT1**Z, means the range is -30-0-30pa/-62.5-0-62.5pa.
DPTL Measuring ranges
Code | UNIT & Ranges |
Accuracy (%FS) |
|||||
Pa | Pa | KPa | In W.C | mm W.C | mbar | DPTL |
|
2 | 0-125 |
125.0 | 0.125 | 0.500 | 12.00 | 1.250 | 2% |
3 | 0-250/500/1000 | 250.0 | 0.250 | 1.000 | 25.00 | 2.500 | 1% |
500.0 |
0.500 | 2.000 | 50.00 | 5.000 | 1% | ||
1000 | 1.000 | 4.000 | 100.0 | 10.00 | 1% | ||
6 | 0-2500 | 2500 | 2.500 | 10.00 | 250.0 | 25.00 | 1% |
7 | 0-5000 | 5000 | 5.000 | 20.00 | 500.0 | 50.00 | 1% |
8 | 0-10000 | 10000 | 10.00 | 40.00 | 1000 | 100.0 | 1% |
9 |
0-20000 | 20000 | 20.00 | 80.00 | 2000 | 200.0 | 1% |
Note: 1. Code 3 has multiple ranges which could be jumper selected.
2. Set the 5 engineering units by button keys and the related LCD indicator will be on.
3. For zero center models, add“Z”at the end of the model. For example, DPTL2**Z, meansthe range is -62.5-0-62.5pa. Only ranges 2~6 have this selection.
Sample Order |
Order |
OEM Order |
Three work days | 2 weeks | 3 weeks |
Port
Shenzhen, Hong Kong