Brand Name: LYTTE OEM
Model Number: LTLS
Place of Origin: Shandong, China (Mainland)
Water Cooled Chiller
1.Semi Hermetic Screw Compressor
2.R22, R407C, R134a
3.Central Air Conditioning Cooling
4.CE, ISO,CRAA
LTLS Series Screw Type Water Cooled Chiller
LTLS Series Screw Type Water Cooled Chiller (Chiller with Screw Compressor 100-2000KW) Features:
1. 40 sizes available ranging from 100 kW to 4000 kW cooling capacity, with heat recovery and low temperature output;
2.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
3. Semi-hermetic screw compressor for all models. Each compressor is equipped with a crankcase heater and a thermal overload cut-out, the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.
4. The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.
5. The unit is of high performance as they are made of the condensers and evaporators of grooved copper pipes, and high quality components, by specialized process.
6. The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.
7. LCD display, touch screen control panel as standard.
8. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
9. For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.
OPTIONAL
Electronic expansion valve
Desuperheater(Heat Recovery) as optional.
Electronic controller with BMS system.
Low noise compressor cabinet or outside full cover.
Channel Steel base
Water Cooled Chiller in Warehouse:
LTLS Series Screw Type Water Cooled Chiller Model Details:
LT L S -- 180 D B H
LT--LVTE Company Products Code
L--Screw Compressors
S—Water Cooled Type Chiller, Cooling Only
180-- Cooling Capacity (Tons)
D-- Double Compressor Model/S—Single Compressor Model
B—Refrigerant Type; --:R22 / A: R407C / B: R134A
H: with partial heat recovery/ Q: with total heat recovery/ --: Standard version
LTLS-*S(D) Series Single Compressor Unit Models:
-Semi-hermetic Screw Compressors Units;
-Most used for Central Air Conditioning Cooling System;
-Evaporator Chiller Water Inlet/Outlet Temperature: 12℃/7℃; Condenser Cooling Water Inlet/Outlet Temperature: 30℃/35℃;
-Heat Recovery is an optional.
-Single Compressor Unit Model: LTLS-30S÷LTLS-250S (Cooling Capacity: 100-970KW)
Remark:
1.Colling Condition: Chilled water in/out 12/7℃; Cooling water in/out 30/35℃;
2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
4. There may be Changes for improvement without notice, confirm always before your order.
Single Compressor Models Size:
-Double Compressors Unit Model: Model: LTLS-60D÷LTLS-500D (Cooling Capacity: 200-1940KW)
Remark:
1.Colling Condition: Chilled water in/out 12/7℃; Cooling water in/out 30/35℃;
2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
4. There may be Changes for improvement without notice, confirm always before your order.
Double Compressor Models Sizes:
LTLS Series Screw Type Water Cooled Chiller System Control:
1. Imaged system operation chart, showing the temperature of water in/out, the energy level of compressor run, on/off button, run time, alarm etc. And the remote turn on/off function is available. PC remote control is optional.
2. Notice for maintenance is indicated according to the accumulated run time of the compressor.It is convenience to maintenance.
3. The control system will automatically balance the run time for each compressor for mult-compressor unit.
LTLS Series Screw Type Water Cooled Chiller (Chiller with Screw Compressor 100-2000KW) Safety Protections:
1. Discharge check value: it prevents the discharged gas from going back after the compressor stops.
2. Phase lack protection: It protects the compressor for over high voltage, voltage deficiency, and phase lack.
3. Direction protection: It protects the compressor from damage resulted from Counter direction run.
4. Oil heater: It heats the oil before the unit start; keep the good lubrication for the unit before it runs.
5. Overheat protection inside the motor of the compressor: It protects the compressor from burning down for too high coil temperature for overload, or abnormal run condition.
6. High&low pressure protection: It protects the compressor and system against extreme run condition and trouble.
7. Freezing protection: It protects the unit form too low temperature of the water out, freezing may occerat some place, resulting in freezing breaking of the evaporator.
8. Water flow protect: It protects the unit from run without water flow.