Brand Name: LYTTE
Model Number: FP
Place of Origin: Shandong, China (Mainland)
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Products Description:
The FP series water fan coil units are designed specially to meet the varied requirements of zone cooling or heating using chilled water or hot water. Fan coil can be applied to 2 pipes 2, 3 rows or 4 Pipes 4 (3+1) rows systems to satisfy the requirements of a wide variety of air conditioning or heating purpose application. The FP series is available in concealed versions for ceiling duct installation. This unit is presented as a single block including: fan deck, cooling or heating coil,
The FP series water fan coil units are designed specially to meet the varied requirements of zone removable filter, drip tray, electrical connection box.
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Main Features:
a) FRAME AND STRUCTURE
Fan Coil Panels & frame are made of galvanized steel, properly punched and punched for fixing both accessories and the unit itself;
b) COOLING OR HEATING COIL
The Coils are made of seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily accessible vent and drainage valve;
c) FAN DECK
Fan decks are composed of double suction centrifugal fans with aluminum impellers and 3-speed fan motors. Each motor assembled is dynamically balanced;
d) DRIP TRAY
The drip trays are made from sheet metal treated with polyester powder coating to ensure the resistance to atmospheric agents;
e) Fan Coil FILTER
Easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum frame. The filter is installed on the units with plenum only;
f) ELECTRICAL CONNECTION BOX
All electric wires are connected to enclosed electrical terminal block, situated on the same side of the water connections;
g) OPTIONAL
3 speed switch (High-Middle-Low);
ON-BOARD THERMOSTART;
Mechanical or Digital type thermostat for two pipe system use, working mode selection (OFF-Heating-Cooling), ventilation (HIGH-MED-LOW) and room temperature setting.
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Model Specifications:
2Pipes Fan Coil, Fan Coil Unit, Chilled Water Fan Coil System Technical Specifications:
Notes:
1) H-Fan High Speed; M-Fan Middle Speed; L-Fan Low Speed;
2) *-Cooling and Heating Data are referred to following Conditions:
Cooling: room temperature: 27℃ 50% RH, chilled water temperature: 7/12℃, high speed;
Heating: room temperature: 21℃, water inlet temperature: 60/50℃, high speed;
3) **-Sound pressure measured in anechoic room 1.5 m away from the unit;
4) ***-Power Supply if 60HZ needed, please inform when order.
4Pipes Fan Coil, Fan Coil Unit, Chilled Water Fan Coil System Technical Specifications:
Notes:
1) H-Fan High Speed; M-Fan Middle Speed; L-Fan Low Speed;
2) *-Cooling and Heating Data are referred to following Conditions:
Cooling: room temperature: 27℃ 50% RH, chilled water temperature: 7/12℃, high speed;
Heating: room temperature: 21℃, water inlet temperature: 60/50℃, high speed;
3) **-Sound pressure measured in anechoic room 1.5 m away from the unit;
4) ***-Power Supply if 60HZ needed, please inform when order.
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Dimension and Weight:
-Dimensions Without Plenum and Filter Form
-Dimension With Plenum and Filter Form
-Fan Coil Exact Dimensions and Weights
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Accessories:
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Installation Diagram:
-Air Duct Installation Instruction:
-Water Pipes Connection Diagram:
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Installation Operation Cautions:
1. Please keep the unit horizontal when installation. The side of condensate water outlet should be slightly lower for easily discharging water. The slope of condensate pipe should be lower than 0.005.
2. Inlet and outlet pipes should have insulation in order to avoid the leakage of condensate water. To avoid the copper pipe rupture in the coil, it’s strictly forbidden to install pipes in a single direction.
3. Valves should be installed in inlet and outlet water pipes so that it easily cuts off the power when adjusting the flow and overhaul the units.
4. The drain pipes of the condensate water plate should not be squashed and bent to insure the water flow unimpeded.
5. In summer, the chilled water supply should not be less than 7 ℃; in winter, hot water supply should not be higher than 80℃. The supply water should be kept clean and soften.
6. Unit return pipes are armed with manual air release valve which must be open when the unit is running and closed when the air in the coil and pipes is completely exhausted.
7. The grounding bolt on the unit covering should be connected with protective grounding system when installation.
8. The heat exchanger coil must be cleaned regularly to ensure good heat transfer performance; Unit with filter must be cleaned often to ensure the best condition of air return.
9. Unit Power request: 220±10%; 50HZ; Wiring connection must be as per the attached Electrical Circuit Diagram; The connected wire color is required to be consistent with wiring signage.
10. Unit after installation, firstly turn the fan impeller by hands. It is allowed to turn on the unit if there is no mechanical friction sound.
11. When soft joint is connected with the unit, pay attention to the seal with the pounded water joints. Don't overexert in case that the copper tube is damaged.
12. Installation must be as per the specification; any damage caused by misuse, the manufacturer is not responsible.
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Wiring Connection Diagram:
Founded in 2002, located in International Kite Capital Weifang City, Near Beijing and Qingdo Port. We are professional manufacturer of HVAC Equipments including Chiller (Air Cooled Chiller, Water Cooled Chiller, Water Chiller), Heat Pump (Water to Water Heat Pump, Air to Water Heat Pump, Water Source Heat Pump, Air Source Heat Pump, Ground Source Heat Pump, Geothermal Heat Pump), Fan Coil Unit(Duct Fan Coil, Ceiling Fan Coil, Cassette Fan Coil, Floor Fan Coil), Air Handling Unit (AHU, Ceiling and Cabinet AHU), New Air Heat Exchange Units etc. and Refrigeration Equipments and Parts includingCondensing Unit (Copeland, Bitzer, Danfoss Units etc), Evaporator, Condenser, Compressor Racks etcfor cold storage, freezer, blast freezing. Our products have rewarded of CE, ISO, UL, BV etc international certificate.
We have the advantages:
Quality Assurance
Excellent After-sales Service
Professional Technical Teams
Delivery on Time
Communication in Time
Competitive Prices
So welcome to inquiry us anything you want.
-Projects Design, Issuing the HVAC system drawings;
-Making quotation for the projects;
-Technical Support, System Guidance;
-Engineers sending to overseas for installation;
-Producing high quality equipments for the HVAC, Refrigeration projects;
-Installation, Maintenance Services;
Chilled Water Fan Coil, Horizontal Fan Coil, Concealed Duct Fan Coil Unit, Water Fan Coil Certificate: