Brand Name: PEIDE
Model Number: PDC
Place of Origin: Jiangsu, China (Mainland)
UV disinfection system for water
Range of uv disinfection system application
UV disinfection system working principle
UV disinfection is the international industrialized latest water disinfection technology,which is with thirty years of research and development in the late nineties. Application of UV disinfection is among 225 ~ 275nm, peak wavelength of 254nm ultraviolet spectrum of microbial nucleic acid to destroy the original body (DNA and RNA), thereby preventing protein synthesis and cell division, they ultimately can not replicate the original body of microorganisms, not genetic and eventually death. Ultraviolet disinfection disinfect fresh water, sea water, all kinds of sewage, as well as a variety of high-risk pathogenic body of water. Ultraviolet disinfection sterilization is the world's most efficient, the most widely used technology, the lowest operating costs of high-tech water disinfection products.
UV disinfection system Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
UV disinfection system Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
UV disinfection system Maximum Concentration Levels (Very Important)
Iron |
≤0.3ppm(0.3mg/L) |
Hardness |
≤7gpg(120mg/L) |
Turbidity |
<5NTU |
Manganese |
≤0.05ppm(0.05mg/L) |
Suspended solids |
≤10ppm(10mg/l) |
UV Transmittance |
≥750‰ |
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV disinfection system UV wavelength (nm)
Bacterial cells will die in the UVC(200-280mm) irradiation. 253.7nm spectral line of low pressure mercury lamp has high bactericidal effect and concentrates more than 900‰ output energy of low-pressure mercury UV lamp
UV disinfection system UV Dose
The units generate a UV dosage of at least 30,000microwatt-seconds per square centimeter (μW-s/cm2), even at the end-of lamp life(EOL), which is more than sufficient to destroy most waterborne microorganisms, such as bacteria, yeasts, algae etc….
DOSAGE is the product of intensity & time dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter (μW-s/cm2) Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2) |
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies |
850-980‰ |
De-ionized or Reverse Osmosis water |
950-980‰ |
Surface waters(lakes, rivers, etc) |
700-900‰ |
Ground water(wells) |
900-950‰ |
Other liquids |
10-990‰ |
UV disinfection system size
Model No | Flow Rate (m3/h) |
All Lamps Power (W) |
In / Outlet diameter |
Chamber dimensions (mm) |
||
mm | inches | |||||
PDCn-030 |
1 |
40 |
20 |
ZG 3/4" |
1000×Φ76 |
|
PDCn-050 |
2 |
40 |
25 |
ZG 1" |
1000×Φ89 |
|
PDCn-080 |
3 |
40 |
25 |
ZG 1" |
1000×300×Φ108 |
|
PDCn-150 |
6 |
80 |
32 |
ZG 1-1/4 |
1000×300×Φ108 |
|
PDCn-200 |
8 |
120 |
40 |
ZG 1-1/2 |
1000×400×Φ159 |
|
PDCn-300 |
12 |
160 |
50 |
ZG 2" |
1000×400×Φ159 |
|
PDC-360 |
15 |
200 |
65 |
ZG 2-1/2" |
1000×400×Φ159 |
|
PDC-500 |
20 |
240 |
65 |
ZG 2-1/2" |
1000×500×Φ219 |
|
PDC-600 |
25 |
280 |
80 |
Flange 3" |
1000×500×Φ219 |
|
PDC-700 |
30 |
320 |
100 |
Flange 4" |
1000×500×Φ219 |
|
PDC-1000 |
40 |
360 |
100 |
Flange 4" |
1000×500×Φ219 |
|
PDC-1300 |
50 |
435 |
125 |
Flange 5" |
1000×570×Φ273 |
|
PDC-1500 |
60 |
450 |
150 |
Flange 6" |
1700×570×Φ273 |
|
PDC-1700 |
70 |
525 |
150 |
Flange 6" |
1700×570×Φ273 |
|
PDC-2000 |
80 |
560 |
150 |
Flange 6" |
1700×570×Φ273 |
|
PDC-2500 |
100 |
700 |
150 |
Flange 6" |
1700×570×Φ273 |
|
PDC-3000 |
125 |
840 |
150 |
Flange 6" |
1700×570×Φ273 |
|
PDC-4000 |
150 |
1120 |
200 |
Flange 8" |
1700×570×Φ325 |
|
PDC-5000 |
200 |
1400 |
200 |
Flange 8" |
1700×570×Φ377 |
|
PDC-7000 |
300 |
2100 |
250 |
Flange 10" |
1700×570×Φ426 |
|
Drain inch |
G 1/2" |
|||||
Lamp useful life |
9000 Hour |
|||||
UV lamp brand |
" Lightsource" from USA |
|||||
Single UV lamp |
40w in general. We can aslo supply 75w, 85w, 155w, 240w, 320w |
|||||
UV lamp select |
If you need we can aslo supply UV lamp which can generater ozone |
|||||
Chamber pressure |
Rated to 0.6Mpa. If you need higher pressure, please tell me |
|||||
Water temperature |
The appropriate temperature is 4 - 50 DEGREE (-5-60 degree range) |
|||||
Packing |
Wooden packaging |
|||||
Optional |
UV intensity monitor system |
|||||
Water temperature monitor system |
||||||
Time accumulator system |
||||||
Cleaning system: Maunal cleaning, Pneumatic cleaning and Electric cleaing |
UV disinfection system lamps
UV disinfection system Quartz tube
UV disinfection system Composition:
CUSTOMERS
OFFICE ENVIRONMENT
CERTIFICATES
Contact us , you will get more than what you see !!
FAQ
Do you have certificates?
Yes , we have ISO certificate and certificate of patent
Do you have design team?
We have a professional design team provide drawings, we wait for your confirmation and production
Can you guarantee delivery time ?
Timely transport, ensure the delivery time
Are you maufacturer ?
Yes, we are the professional water treatment equipment manufacturer in china