Brand Name: ANLT, ANLT
Model Number: ALTGV2R, ALTGV2R
Place of Origin: Sichuan, China (Mainland), Sichuan, China (Mainland)
Application:
Public&office buildings,Club,Snow melting,Animal husbandry system,
Standard:
ALTGV1R ALTGG1R ALTGV2R,
Certifacation:
ISO90012000 ROHS CE
Voltage:220V
Power per metre: 18W
We can also produce based on cosumers' request
The Strength of OIur Cable Underfloor Heating Wire:
1. Double shielding of Aluminium foil and Aluminium net that is made by 96 pieces, in usual it is single shielding.
2. Long life Heater Core that can stand high temperature of 180 centigrade, in usual it is lower than 180 centigrade
3. Take use of insulating material of Anti Flame Silicon Rubber, in usual it is the best materials.
4. Double heating with even temperature, in usual it is single heating.
5.Meets UL standards and features with 12 years warranty,longest warranty time
Specification For Reference:
1. Our product is made by Albata or Fe Cr Al (Materials)
2. The In-slab heat cable is only 6mm diameter
3. The number of core: 1 or 2
4. Inner insulation: silicone rubber
5. Sheath: high termperature resistent PVC
Single comductor floor heating cable
Standard | Totle resistence(ohm) | Length(m) | Total PowerW |
ALTGV2R | 161.33 | 16.7 | 300 |
121 | 22.2 | 400 | |
96.8 | 27.8 | 500 | |
80.67 | 33.3 | 600 | |
69.14 | 38.9 | 700 | |
56.94 | 47.2 | 850 | |
48.4 | 55.6 | 1000 | |
40.33 | 66.7 | 1200 | |
34.57 | 77.8 | 1400 | |
30.25 | 88.9 | 1600 | |
26.89 | 100 | 1800 | |
24.2 | 111.1 | 2000 | |
22 | 122.2 | 2200 | |
20.17 | 133.3 | 2400 | |
18.62 | 144.4 | 2600 | |
prodution process:
some samples:
office and workshop:
certifates:
Frequently Asked Questions
Q: Is there electromagnetic radiation to the human body by using ANLT Floor Heating System?
A:The heating cable of ANLT Heating Cable Floor Radiant Heating System adopts the double-screen construction,can effectively reduce the electromagnetic radiation,so it is very safe and will not produce electromagnetic radiation on the human body.
Q:Does the cable have the electric-leakage problem ?
A:The electric heating products lack of strict quality control and application experience may have hidden danger of electric leakage.But ANLT heating cable uses the sophisticated design and production technology,with the multiple safe protection devices such as the electric-leakage protection,so it can be assured for safe use.
Q:Dose ANLT Heating Cable Floor Radiant Heating System have huge power consumption ?
A:The power consumption of ANLT Heating Cable Floor Radiant Heating System depends on many factors such as the hours of use,temperature setting ,and heating conservation,and intelligent temperature control system,you can save huge electricity bills.
Q:What’s the difference between ANLT Heating Cable Floor Radiant Heating System and traditional hot-water heating system ?
A:The structure of ANLT Heating Cable Floor Radiant Heating System is simple,temperature of the room is more even,temperature control is more accurate too,in addition,for comparing,the hot-water heating system has the disadvantages of the difficult of sectional temperature control and huge investment on installation;the heating temperature is different too,hot-water system has a highter temperature but having a higher requirement for the floor materials
Q:Which are the requirements for installing the ANLT Heating Cable Floor Radiant Heating System?
A:It is very simple for installation,only need a certain height of the structure layer,including heat-conservation layer,generally about 3-5 centimeters. In addition,for safety requirement,you need certain power capacity installation.
Q:How long will it last ?
A:The ANLT Heating Cable products provide 12 years’ quality guarantee.According to different operating conditions ,the whole heating system can be used for 50 years without maintenance.
Q:What are the main difference between ANLT Heating Cable Floor Radiant Heating System and traditional heating system ?
A:It is more comfortable by using ANLT Heating Cable Floor Radiant Heating System than the traditional heating system; ANLT Heating system adopts the “invisible installation”,which will not impact the decoration of the internal design of your houses;temperature in different rooms can be controlled separately;without noise impace and dry feeling.
Q:What are the floor material requirements for installing the ANLT Heating Cable Floor Radiant Heating System ?
A:Many kinds of floor materials can be used for installing ANLT Heating Cable Floor Radiant Heating System.Such as ceramic tiles and marbles,which distribute the temperature fast and provide most comfortable feeling.
Our minimum order is 1000 meters
FOB port is in Shenzhen and Shanghai of China
Delivery price is depend on how many products you order
(For example: 1000 meters exports from US to China is about: 450USD)
Delivery time is about one week from China to USA
Payment Method: T/T and L/C
Packaging: Karton
Please visit our official websites for more info: www.cdanlt.com
Please visit alibaba website for more info: http://cdanlt.en.alibaba.com/