Brand Name: CH-BA
Model Number: RH-5U-D
Place of Origin: Shanghai, China (Mainland)
Features
· Humidity measurement for air ducts
· Simple and secure installation
· 0-10V or 4-20mA measuring signals
· Compact size and modern design
Applications
· On return air ducts to measure return air humidity
· On supply air ducts to measure supply air humidity
· On fresh air ducts to measure outdoor air humidity.
Humidity Tansmitter
The transmitter measures the humidity by the honeywell humidity sensor HIH-3610. The transmitter analog output may be be 0-10V or 4-20mA. And the transmitter include a noise filter.the power suply is large range VDC18V----VDC30V.The humidity transmitter measurement range is 5%-95%.
Ordering
Ordering number:RH-5I-D or RH-5I-D-T
-5 indicates the humidity transmitter accuracy is 5%; -3 indicates 3%, -2 indicates 2%.
-I indicates the humiditt transmitter signal out is 4-20mA. If U indicates the signal is 0-10V.
-T indicates the humidity transmitter integration with temperature signal out.
For example:RH-5I-D-T
The duct humidity transmitter signal out is 4-20mA and the temperature signal out is 4-20mA.
InstallationDuct probes should be installed directly on the duct, in an area where the air stream is well mixed:
· Locate a supply air sensor two or three meters down stream from the nearest fan and coil.
· Mount the return air sensor close to the air inlet but downstream from a return fan if one is present.
· To install the sensor, assemble base plate and probe, then drill a 12 mm hole and two 3 mm holes on a diameter of 25 mm in the duct.
· Use two self-tapping sheet metal screws to tighten the mounting circuit in the cover.
· Connect the wires according to the wiring diagram to the measuring circuit in the cover:
o Only the humidity transmitter signal out need three terminal connections,DC24V,Ground and humidity signal out.
o If humidity and temperature transmitter signal out need for terminal connections,DC24V,Ground,humidity signal out and temperature signal out.
o The connection signal cable should be shield wires.
· Assemble the cover with the mounting plate.
· Insert the assembled probe through the center opening of the mounting plate into the air stream.
· Tighten the horizontal screw on the mounting plate to fix the probe to the duct.
Power suply |
Option voltage |
VDC18V---VDC30V |
Power Cunsumption |
Max 2 VA |
|
Signal out |
signal |
4-20mA |
accuracy |
5% |
|
Humudity range |
0%-100% |
|
Sensing element |
Capacitive Element: Range Accuracy |
5%---95% ±0.3k |
Connection |
Connection Terminals |
2.5 mm2 |
Environment |
Operation |
To IEC 721-3-3 |
Transport & Storage |
To IEC 721-3-2 and IEC 721-3-1 |
|
Standards |
conform according to |
|
Automatic electrical controls for household and similar use Special requirement on temperature dependent controls |
EN 60 730 1
EN 60 730 2 - 9 |
|
Pollution Class |
Normal acc. To EN 60 730,RoHS compliant |
|
Degree of Protection |
IP56 to EN 60 529 |
|
|
Safety Class |
III (IEC 60536) |
Housing Materials |
Cover & Mounting Plate |
Fire proof ABS plastic |
General |
Dimensions [mm] |
Cover: 42 x 112 x 88 (H x W x D) probe: ø 10 x 200 (Diameter x L) |
Weight (including package) |
135g |