Brand Name: OEM
Model Number: KS35-C300 (series R2)
Place of Origin: Guangdong, China (Mainland)
Product has passed the EN16147 test.
Air Source Heat Pump All in One Type
Top Discharge with Double Ducts
Heat pump is a device in which the refrigerant R410A is continuously changing the shape from gas to liquid. It pumps out the solar energy from the air in the room and together with electrical energy consumed by compressor it gives out the total heating capacity which is accumulated in the water storage tank.
Evaporator is an air-refrigerant heat exchanger. In the evaporator the refrigerant is vaporized at low pressure and relative low temperature. Because of vaporization the heat transfer form air to refrigerant starts. Vaporized refrigerant comes in the compressor where the pressure goes higher and also the temperature. From compressor the vaporized and high temperature steam goes in the condenser (refrigerant-water) where again the heat is transferred from refrigerant to water. The refrigerant is now in liquid shape idler high pressure. After it flows thought the expansion valve it reaches the basic shape and he process goes around again. The circuit is on process until the water temperature in the water storage tank reached the set point.
DOMESTIC HEAT PUMP WATER HEATER-----All in one-2 series R2 specification(R410a)
KS35-C300 | |||
Technical Data | Rating temperature of output water | ℃ | 55 |
Max temperature of output water | ℃ | 65 | |
Heating capacity | KW | 3.4 | |
Water yield(Fr 25℃ to 55℃) | L/H | 75 | |
Rating power input | KW | 1.06 | |
Max power | KW | 2.1 | |
Noise level | dB(A) | 48 | |
Compressor | Type | Rotary | |
Additional electrical heater(option) | KW | 2 | |
Air pressure | Pa | 60 | |
Installation | Unit dimension | DXH(mm) | Φ650X1845 |
Packing dimension | WXDXH(mm) | 700X700X1880 | |
Water tank volume | L | 300 | |
Net weight | Kg | 98 | |
Duct diameter | mm | 150 | |
Water inlet/outlet connection | 3/4" | ||
Running condition | Power | V/Ph/Hz | 230/1/50 |
Rating current inupt | A | 4.8 | |
Max current | A | 9.2 | |
Work Temperature | ℃ | 0~40 |
Option: 1. with solar coil, 2. with electrical heater