Technical Parameters:
Model |
LX-0250 |
LX-0400 |
LX-0700 |
LX-1000 |
LX-1450 |
LX-2000 |
|
Medium Temperature Range |
-15℃~30℃ |
-25℃~30℃ |
-25℃~30℃ |
-25℃~30℃ |
-25℃~30℃ |
-25℃~30℃ |
|
Temp. control |
ASET multifunctional controller |
||||||
Temp. control optional |
Heat-conducting medium outlet temp. control |
||||||
communication protocol |
MODBUS RTU Protocol, RS 485 Interface |
||||||
Temp. feedback |
Heat-conducting medium temperature feedback PT100 |
||||||
Cooling capacity |
0℃ |
1.5kW |
2.4kW |
4kW |
7.5kW |
10kW |
15.5kW |
-10℃ |
1kW |
1.5kW |
2.7kW |
6.3kW |
8kW |
12kW |
|
-20℃ |
0.55kW |
0.8kW |
1.5kW |
3.5kW |
5kW |
7.3kW |
|
Circulation pump |
Max20L/min 0.7BAR |
Max20L/min 0.7BAR |
Max35L/min 1BAR |
Max50L/min 1BAR |
Max75L/min 1BAR |
Max75L/min 1BAR |
|
capacity of liquid storage |
15L |
25L |
30L |
35L |
45L |
60L |
|
Compressor |
Tecumseh |
Tecumseh |
Copeland |
Copeland |
Copeland |
Copeland |
|
Evaporator |
Plate heat exchanger |
||||||
Operating controller |
Display setting temperature and testing temperature; Touch key display |
||||||
Security protection |
Self-diagnosis function; freezer overload protection; high pressure switch; overload relay, thermal protection device etc. security protection function. |
||||||
Refrigerants |
R-404A |
||||||
Connection size |
DN-15 |
DN20 |
DN20 |
DN20 |
DN20 |
DN-20 |
|
Product size (air-cooled) |
400*600*1050 |
400*600*1150 |
500*680*1350 |
550*680*1450 |
620*680*1550 |
750*750*1750 |
|
Weight (air-cooled) |
115KG |
145kg |
180kg |
225kg |
290kg |
340kg |
|
Power |
AC220V 50HZ 1.5kW (max) |
AC220V 50HZ 2.2kW (max) |
AC220V50HZ 3.5kW (max) |
AC380V 50HZ 4kW (max) |
AC380V 50HZ 5kW (max) |
AC380V50HZ 6.5kW (max) |
|
Material |
Cold rolled steel |
||||||
Optional |
Match 7-inch color touch screen controller, temperature curve record, data export to excel format. |
||||||
Optional |
Circulation Pump Optional: 35L/min 2.5bar 50L/min 2.5bar 110L/min 2.5bar |
||||||
Optional |
SUS304 material |
||||||
Optional |
Pressure max. 10 bar circulating pump |
||||||
Optional Power |
220V 60HZ three-phases, 440V~480V 60HZ three-phases |
||||||
Remark |
Can make the bigger capacity of water storage as required. |
Wuxi Guanya Refrigeration Technology Co., Ltd. Specialized in rerfigeration unit,
ultra-low temperature freezer, cooling and heating temperature control system,
heating circulation system, explosion-proof electric equipment. Automatic integrated
disparate control system, laboratory apparatus. We are the technology leader for
high precision thermoregulation solutions in Research and Development Industry.
Our products ensure precise temperature control throughout the whole world in
laboratories, pilot plants and production processes. Our product range offers temp.
control solutions for applications from -152 to +350℃.
We make market and user need oriented products, focusing on science and tech.
applying international advanced technology, endlessly get rid of the stale and bring
forward the fresh following the market step & meet market demand. The company
always insists on standardised management in accordance with ISO9001-2008
international quality certification requirement from product design, purchase and
selection of components, to production process flow, packaging and transportation
etc, try to keep improving products, and keep reasonable price and satisfactory
service.
Development history
In 2006 Start production of refrigeration and heating system equipments.
In 2007 Developed the first generation of refrigeration and heating thermostat and
establish the LNEYA CO., LTD.
In 2008 Developed the first generation of refrigeration and dynamic temperature
control system.
In 2009 Developed the second generation of refrigeration and heating thermostat.
In 2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
Developed the second generation of refrigeration and heating dynamic temperature
control system.
Developed the refrigeration and heating dynamic temperature control system &
low temperature freezer for industry use.
In 2011 Developed new technology with single compressor having multiple circulation
systems (can reach to -80 degree with single compressor)
Upgraded the second generation of refrigeration and heating dynamic temperature
control system.
In 2012 Single compressor having multiple circulation systems is applied in production
of SUNDI-4, SUNDI-5, SUNDI-6, and SUNDI-7, SUNDI-8 and LT series.
Upgraded the second generation of refrigeration and heating dynamic temperature
control system for the second time and developing the third generation of refrigeration
and heating dynamic temperature control system.
In 2013 Developed new product one operating multi refrigeration and heating temp.
control system(the third generation of refrigeration and heating dynamic temperature
control system).At the same time testing the large capacity of ultra-low temperature
freezer.
In 2014 Developed with large capacity of ultra-low temperature freezer which used for
industrial production,new goods will be research.And it will be launched in the market
soon........