The Newest Vertical Freezer Thermostat Switch SF-783
Feature
1.Temperature display&control
2.Defrost type optional
3.Self testing/Defrost control/Power switch
Technical Data
1.Range of temperature displayed:-50°C~150°C(-50~302°F)
2.Range of set temperature:-50°C~45°C(-50~113°F)
Accuracy:±1°C(1°F)
3.Temperature sensor: NTC, two sensors, 2 meters (Neither positive nor negative)
4.Compressor :NO. 30A/250VAC
Defrost: NO. 10A/250VAC
Fan: NO. 8A/250VAC
Light: NO. 8A/250VAC
Circuit diagram
Vertical Freezer Thermostat Switch
Parameter
Paramete |
Function |
Set range |
Default |
PAS |
Password |
00~99 |
15 |
E1 |
Lower setpoint limit |
-50°C/-50°F~Set temp. |
-25°C/-13°F |
E2 |
Higher setpoint limit |
Set temp.~45°C/113°F |
20°C/68°F |
E3 |
Temp.hysteresis |
00~40°C/00~72°F |
04°C/07°F |
E40 |
Comp.start delay time |
00~10Min |
2Min |
E41 |
Delay starting time |
00~10Min |
2Min |
E5 |
Offset on room temp. |
-20~20°C/-36~36°F |
00°C/00°F |
E6 |
Offset on evap. temp |
-20~20°C/-36~36°F |
00°C/00°F |
E7 |
Offset on condenser |
-20~20°C/-36~36°F |
00°C/00°F |
F0 |
Defrost type |
00=Defrost by turning off comp. 01=Heater defrost 02=Hot gas defrost |
01 |
FF0 |
Hot gas defrost comp. delay starting time |
00~20Min |
00Min |
FF1 |
Defrost mode |
00=Power on hours 01=Comp. continuously working time |
01 |
F1 |
Max. defrost duration |
01~60Min |
20Min |
F2 |
Defrost interval time |
00~24Hr |
6Hr |
F30 |
Defrost starting time |
-40°C/-40°F~F31 |
00°C/32°F |