Brand Name: Danfoss
Model Number: QDV15,148H3272-3273
Place of Origin: Tianjin
Shut-off valve QDV15,148H3272-3273 Danfoss Drain valve
QDV is a shut-off valve, designed particularly for
draining oil from systems containing refrigerant
(ammonia) under pressure.
The valve will close immediately on release of the
handle, thus protecting user and environment
against unne cessary refrigerant leaks. The valve
should as a rule be installed as illustrated in fig. 1.
In order to pre vent hydraulic pressure building
up between the stop valve and the QDV an
integral relief device is included as part of the
cone arrangement, which will open at approx. 16
bar (232 psig).
QDV is designed to meet the safety demands
specified by national and international
authorities within industrial refrigeration.
Applicable to R717 (ammonia).
• Meets the safety demands within industrial
refrigeration
• Handle can be positioned 360°
• Built-in integral relief device opening over 16
bar g (proventing hydraulic pressure building
up between shut-off valve and QDV).
• Can be supplied together with a stop valve for
quick on site mounting (fig. 1).
• Max. operating pressure:
40 bar g (580 psi g).
• Temperature range:
–50/+150°C (–58/+302°F).
• Classification: DNV, CRN, BV, EAC etc.
To get an updated list of certification on the
products please contact your local Danfoss
Sales Company.
Connections
Available with the following connections:
• Inlet: Welding DIN (EN 10220)
½ in. FPT
3/4 in. FPT
• Outlet: G 3/4 in. pipe thread (ISO 228/1)
½ in. FPT
3/4 in. FPT
Optional extras for outlet:
– Welding nipple DIN (EN 10220)
– Hose connection
Other types of connection are available on
request.
QDV - SVA combinations
Combinations of the QDV together with a
dedicated SVA have been established for easy
selection. Please study page 6 to find the code
numbers for these combinations.
Installation
For further information refer to installation
instruction for QDV.Connections
Available with the following connections:
• Inlet: Welding DIN (EN 10220)
½ in. FPT
3/4 in. FPT
• Outlet: G 3/4 in. pipe thread (ISO 228/1)
½ in. FPT
3/4 in. FPT
Optional extras for outlet:
– Welding nipple DIN (EN 10220)
– Hose connection
Other types of connection are available on
request.
QDV - SVA combinations
Combinations of the QDV together with a
dedicated SVA have been established for easy
selection. Please study page 6 to find the code
numbers for these combinations.
Installation
For further information refer to installation
instruction for QDV.