Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products News Exhibitions Exhibitors
Ahri210/240 Psychrometric Test Laboratory Ahri210/240 Psychrometric Test Laboratory Ahri210/240 Psychrometric Test Laboratory

Ahri210/240 Psychrometric Test Laboratory

Price:
US 100000-300000 / Piece
Min.Order Quantity:
1 Piece
Supply Ability:
100 sets per Year
Port:
Guangzhou, China
Place of Origin:
China
Payment Terms:
L/C, T/T
Brand:
GZ-LANS
Products Model:
LS-ZL32
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: GZ-LANS

    Model Number: LS-ZL32

    Place of Origin: China

Specifications

AHRI210/240 Psychrometric Test laboratory
1.Synopsis of the laboratory
This facility is used for determining the capacity of Air-con by indoor air enthalpy method and refrigerant enthalpy method. It also measures various kinds of data including pressure and electrical properties of the Air-con.

And it consists of two climate chamber (indoor side and outdoor side room), air handling units, condensing units, airflow measurement apparatus, power panel, computer system and so on.

This facility can not only in accordance with the international standard complete the testing of AC, but also meet the standard AHRI210/240 and prEN14825 of the air conditioning SEER/HSPF evaluation. For this purpose, the degradation coefficient (CD) of UUT can be measured by actual tests series.

2.Testing items
As per the ISO5151-2010
Cooling Tests
Cooling capacity tests (T1, T2, T3)
Maximum cooling performance test
Minimum cooling, Freeze-up air blockage and freeze-up drip performance tests
Freeze-up drip performance test
Heating Tests
Heating capacity tests (high temp, low temp, extra-low temp).
Maximum heating performance test
Minimum heating performance test
Automatic defrost performance test
Tests above including measures of circulation air volume and voltage, ampere, input power, COP.,EER of UUT

3.Inspection Conditions   
Accurate Test----Rated cooling capacity tests in the two sides at the same time.Acceptable differences of indoor air enthalpy method (air side) and refrigerant enthalpy method (refrigerant side)----

For the cooling capacity≥2500W, within 2.5% of difference for one UUT consecutive 3 times test, which the tests are at the same installation condition.
For the cooling capacity2500W, within 50W of difference for one UUT consecutive 3 times test, which the tests are at the same installation condition.
Repeatability test---- Rated cooling capacity tests.
Acceptable difference----
For the cooling capacity≥2500W, within ±1.5% of averaging difference for one UUT consecutive 3 times test, which the tests are at the same installation condition.
For the cooling capacity2500W, within ±35W of averaging difference for one UUT consecutive 3 times test, which the tests are at the same installation condition.
Master sample as compared to tests---- Rated cooling capacity test.
Acceptable difference----
For the cooling capacity≥2500W, ±2% compared to test result from local National Testing Center.
For the cooling capacity2500W, within ±50W compared to test result from local National Testing Center.


For more information, please visit our Website:  www.gzlans.com
 
  • Email to this supplier
  • To :
    Jessica Chan  |  Gz-lans Experimental Technology co., Ltd.
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Gz-lans Experimental Technology co., Ltd. Bussiness Type:  Manufacturer,Trading Company
Scale:  101 - 200 People
Country/Region:  China (Mainland)/Asia
Established:  2018
You May Like:
Multiple Room Psychrometric Test Chamber

Air Conditioner Test Chamber

Air Conditioner Test Laboratory

Enthalpy Potential Method Testing Lab

Multi Psychrometric Test Lab

Ahri210/240 Air Conditioner Test Unit

Vehicle Air Conditioner Laboratory

AC Psychrometric Test Room

<font color='red'>Ahri210</font>/<font color='red'>240</font> <font color='red'>Psychrometric</font> <font color='red'>Test</font> <font color='red'>Laboratory</font>