Brand Name: Clitech
Model Number: CWW-18RB
Place of Origin: Guangdong, China (Mainland)
Parameter list:
Meeting closed loop groundwater source heat pumps
Clitech CWW | CWW-16RB | CWW-20RB | CWW-28RB | ||
Cooling condition | Cooling capacity | Kw | 14.1 | 17.5 | 23 |
BTU | 48122 | 59726 | 78498 | ||
Input power | Kw | 2.95 | 3.7 | 4.8 | |
Input current | A | 5.9 | 7.4 | 19 | |
EER | 4.8 | 4.7 | 4.79 | ||
Heating condition | Heating capacity | Kw | 15.9 | 18.8 | 24.2 |
BTU | 54251 | 65510 | 82570 | ||
Input power | Kw | 4.2 | 5 | 6.3 | |
Input current | A | 8.6 | 10.2 | 32 | |
COP | 3.8 | 3.8 | 3.84 | ||
Max running current | A | 12 | 16 | 20 | |
Power source | V/P/Hz | 380V-415V3N//50HZ | |||
Noise level | dB(A) | <60 | <60 | <60 | |
Unit size W x D x H | mm | 680*800*720 | 680*800*720 | 800*1080*1050 | |
Pack size W x D x H | mm | 780*900*840 | 780*900*890 | 900*1180*1220 | |
Unit weight | kg | 170 | 190 | 210 | |
Water temp control precise | °C | ±2°C | |||
Controller type | LCD control panel with colorful backlight, can receive panel button control and remote infrared control | ||||
Controller function | Work mode control, independent temp setting, work condition display, timer on/off and button lock functions | ||||
Throttle type | external equalizer thermostatic expansion valve | ||||
Refrigerant type | R410A, R407C, R417A optional | ||||
Refrigerant qty | kg | 2 | 2.3 | 2.5 | |
Compressor type | Hermetically sealed scroll compressor(Sanyo, Copeland optional) | ||||
Compressor qty | pc | 1 | 1 | 1 | |
Water source side | Heat exchanger type | Efficient tube in tube heat exchanger | |||
Water flow | m3/h | 1.33 | 1.66 | 2.4 | |
Water pressure loss | kPa | 12 | 12 | 14 | |
Pipe size | DN | 25 | 25 | 32 | |
Max working pressure | kPa | 1000 | 1000 | 1000 | |
Water chiller side | Heat exchanger type | Efficient tube in tube heat exchanger | |||
Water flow | m3/h | 2.42 | 3.01 | 4 | |
Water pressure loss | kPa | 12 | 12 | 14 | |
Pipe size | DN | 25 | 25 | 32 | |
Max working pressure | kPa | 1000 | 1000 | 1000 | |
1.Rated cooling: heat source side inlet water temp 18°C,outlet water temp is 29°C,air conditioning side inlet water temp is 12°C outlet water temp 7°C. 2.Rated heating: heat source side inlet water temp 15°C,air conditioning side inlet water temp 40°C.outlet water temp 45°C. |
CWW series water source heat pumps can be for cooling in summer and heating in winter.
1. Advanced scroll heat pump technologe.
2. Economical and high efficiency.
3. Complete solution meets various needs; all year round heating and domestic hot water supply solution.
4. Wide operation range.
5. Safe operation with multi-protections.
6. Environment friendly R410a refrigerant.
7. Low noise design.
8. Fuzzy defrost.
9. Easy installation & maintenance.
10.Reliable performance at lower ambient temperature.
Each project has its special requirement for installation(open loop or closed loop), if any queries, our engineer will be so glad to make any drawing or suggestion for you! Pls kindly contact us!
Ground source heat pump installation method
Horizontal loops
Pipes are laid horizontally in trenches. The depth of the trenches will vary according to the design and soil condition, but is usually 1.2 to 2m deep to assure year round heat source constant temp. Horizontal loops require much more surface area than vertical loops.
Trenches will need 50-80 metres of pipe per kilowatt (kW), with at least 5 metre distance between trenches with coils.
Note, however, this will depend on a number of factors, including ground conditions.
Vertical loops
Most commercial and institutional projects using ground source heat pumps use ‘vertical loop’ systems, which consists of pipe inserted into vertical bore holes, less space is required.
It dig into the ground, normally around 90 metres deep. It is common to have two bore holes to supply one home. The holes are roughly 200mm wide and must be kept at least eight metres apart from each other.
Slinky coils
“Slinky” is a variation of ‘Horizontal loop’. Slinky coils are flattened coils of overlapping piping, which are spread out and laid either horizontally or vertically. Their ability to focus the area of heat transfer into small volume, it reduces the length of the trenches, so reduced land area may need. A 10m long trench laid with a ‘Slinky’ coil will typically supply 1kW of heating load.