Brand Name: wuhansifang
Model Number: 412X150X293mm
Place of Origin: china
Introduction: Portable flue gas analyzer is designed for portable application to measure up to 9 gases and with optional gas temperature, pressure, flow testing function, with replaceable side-mounted filter, 320*240 LCD display and RS232 output for data logging.
Applications:
Boiler, furnace exhaust emission gas and combustion efficiency monitoring
Cement production line process and security
Combustion and emission control research or certification of
Continuously Emission Monitoring System
Features:
Simultaneous measurement of O2, SO2, CO2, CO low, CO high, HC, NO, H2S(optional),NO2(optional) optional T, P, Flow
NDIR-technology to measure CO high, CO2 and HC
Maximum measure 9 gases: six ECD sensors and three NDIR sensors
Auto ZERO
Built-in pump
Calculation of Lambda and combustion efficiency
LCD 320 x 240 display and RS232 digital output
Weight :6.5Kgs
Specifications:
Specification of Gas Measure |
|||||||||||||||
Components |
Methods |
Normal |
Min Range |
Max Range |
Resolution |
Accuracy |
|||||||||
O2 |
Electrochemistry |
0-25% vol |
0-25% vol |
0-100% vol |
0.01% |
±2% |
|||||||||
CO low |
Electrochemistry |
0-4000ppm |
0-100 ppm |
0-9999 ppm |
1PPM |
±2ppm ±10ppm |
|||||||||
SO2 |
Electrochemistry |
0-2000ppm |
0-100 ppm |
0 -4000 ppm |
1PPM |
± 2ppm ±5ppm |
|||||||||
NO |
Electrochemistry |
0-2000ppm |
0-100 ppm |
0 - 4000 ppm |
1PPM |
± 2ppm ±5ppm |
|||||||||
NO2 Optional |
Electrochemistry |
0-200ppm |
0-100 ppm |
0 -1000 ppm |
1PPM |
± 2ppm ±5ppm |
|||||||||
H2S Optional |
Electrochemistry |
0-1000ppm |
0-200ppm |
0- 1000 ppm |
1PPM |
± 2ppm ±5ppm |
|||||||||
CO high Optional |
NDIR |
0-10% vol |
- |
- |
0,01 % |
± 0,05% |
|||||||||
CO2 |
NDIR |
0-25% vol |
- |
- |
0,01 % |
± 0,05% |
|||||||||
HC |
NDIR |
0-9999ppm |
- |
- |
1ppm |
± 10ppm |
|||||||||
Note: The measured components and range can be customized. |
|||||||||||||||
Specification of Temperature Measure |
|||||||||||||||
Parameter |
Method |
Measure Range |
Resolution |
Precision |
|||||||||||
Flue Gas Temperature |
Thermocouple |
0~800℃ |
1℃ |
±3℃ |
|||||||||||
Ambient Air Temperature |
Thermistor |
0~99℃ |
1℃ |
±1℃ |
|||||||||||
Specification of pressure measure |
|||||||||||||||
Parameter |
Method |
Measure Range |
Resolution |
Precision |
|||||||||||
Diff. Pressure |
Silicon Diff. Pressure Chip |
-50hPa~50hPa |
1Pa |
±2Pa or ±5%rel |
|||||||||||
Ambient Pressure |
Silicon Pressure Chip |
86kPa~120kPa |
0.01kPa |
±0.5kPa or ±2%rel |
|||||||||||
Other specifications |
|||||||||||||||
Communication Interface |
RS232 |
||||||||||||||
Work Temperature |
5~45℃ |
||||||||||||||
Relative Humidity |
5~85% |
||||||||||||||
Ambient Pressure |
86~108kPa |
||||||||||||||
Working power |
AC 90V-240 50Hz±1Hz |
||||||||||||||
Dimension |
438 X 290 X 152mm(W×L×H) |
||||||||||||||
Weight |
About 6.5kg |
Standard accessories:
Sampling probe with thermocouple
RS232 cable
Power supply charger
Optional accessories:
Pitot tube