Air to Water Screw Chiller (LTLF Series)

Air to Water Screw Chiller (LTLF Series)

FOB Price:
USD 200-1800 / Set
Min.Order Quantity:
200 Set
Supply Ability:
3000 Set per Day
Port:
China's important port
Place of Origin:
china ,shandong
Payment Terms:
L/C, D/P, T/T
Brand:
LYTTE
Products Model:
LT W F ----10
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: LYTTE

    Model Number: LT W F ----10

    Place of Origin: china ,shandong

Packaging & Delivery

  • Packaging Details: standard ocean delivery packing
  • Delivery Detail: 30DAY

Specifications

 Air Cooled Chiller Features:
1.With scroll, or reciprocating compressor of high quality, high efficient heat exchangers, excellent system design, by excellent process, the chillers is of suffient capacity and efficiency.
2.The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components and professional control procedure.
3. Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
4. 3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
5. External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.
6. Evaporator built with high efficiency tube in tube type heat exchanger, factory insulated with flexible close cell material.
7.Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.
8. Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve high & low pressure switch.
9. Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.
10. Electric panel consist of: compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit).
11. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
12. Complete safety protection:
a. High&low pressure protection, pressure safety value protection;
b. Overload protection to the compressor;
c. Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;
d. Water system protection for freezing breaking, water lack etc.

Applicable Industries
-Industrial Reaction Kettle Cooling -Central Air Conditioning System -Chemical Industry.
-Plastic Injection Cooling -Pharmaceutical Industry.

Two Kinds of Models: Air Cooled Water Chiller/Air to Water Chiller
1. Design Cooling Condition: Chilled Water In/Out 12℃/7℃;Ambient 35℃
Models: LT03AS-40AD Cooling Capacity: 8KW-120KW
-Hermetic Scroll or Semi-hermetic Piston Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Water Inlet/Outlet Temperature 12℃/7℃,Ambient 35℃
-Mostly Used for Central Air Conditioning Cooling

 

Remark: 1.Colling Condition: Chilled water in/out 12/7℃;Ambient Temperature 35℃;
2. Suitable chilled water temperature: 7-25℃;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.

2.Cooling Condition: Chilled Glycol in/out -1/-5℃; ambient 35℃
Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW
-Hermetic Scroll Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Glycol Inlet/Outlet Temperature -1℃/-5℃, Ambient 35℃
-Mostly Used for Industrial Processing Cooling

 

Remark:1.Designed Condition:Chilled Glycol in/out -1/-5℃; ambient 35℃;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.

System Diagram

 
  • Email to this supplier
  • To :
    Mr. Jack Jin  |  SHANDONG LVTE AIR CONDITIONING SYSTEM CO.,LTD
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - SHANDONG LVTE AIR CONDITIONING SYSTEM CO.,LTD Bussiness Type:  Manufacturer,Trading Company
Scale:  101 - 200 People
Country/Region:  China (Mainland)/Asia
Established:  
You May Like:
Cassette Ceiling Type Fan Coil Unit

Wall Mounted Type Fan Coil Unit

Vertical (Floor Standing) Type Fan Coil Unit

Horizontal Exposed Type Fan Coil Unit

Geothermal Ground Source Heat Pump (With Scroll Compressor)

Water to Water Heat Pump (Household Type with Sroll Compressor)

Water Source Heat Pump (With Scroll Compressor)

Air Cooled Water Chiller (With Scroll or Piston Compressor)