Brand Name: Galaxy
Model Number: HT-G1
Place of Origin: Shaanxi, China (Mainland)
2016 GALAXY New Design For Floor Warming Electrical Heating Cable
Product Description
Our company's electric heating cable can be widely used in residential, office and various types of aquaculture of the winter heating, vegetables, flowers, nursery, breeding, aquaculture hatching greenhouse greenhouse construction.
Single conduction heating cable:
1, materials: copper alloy,
2, number of core: 1
3, screen: dual layers (copper coil shielding + aluminum foil shielding )
4, sheath: high-termperature-resistent PVC or high-temperature-resistent silicon rubber
5, power range: 300w-3000w,
6,rated voltage: 220v
7, Power(w/m):18w 20w 30w
8. Color: RED, BLUE,BLACK
Dual conduction heating cable:
1,materials: copper alloy,
2,number of core: 2,
3,screen: single layer (copper coil shielding)
4,sheath: high-termperaure-resistant PVC or hight temperature-resistent silicon rubber
5,power range:300w-2600w,
6,rated voltage:220v
7,power(w/m): 18w 20w 30w
8. Color: RED, BLUE,BLACK
Samples help you divided the twin conductor and single conductor:
The basic specification for both singlge conductor and duaconductor as below:
specification |
Nominal |
Length |
Total power |
specification |
Nominal |
Length |
Total power |
|
161.33 |
16.7 |
300 |
dual-conductor underfloor heating cable |
161.33 |
16.7 |
300 |
121 |
22.2 |
400 |
121 |
22.2 |
400 |
||
96.8 |
27.8 |
500 |
96.8 |
27.8 |
500 |
||
80.67 |
33.3 |
600 |
80.67 |
33.3 |
600 |
||
69.14 |
38.9 |
700 |
69.14 |
38.9 |
700 |
||
56.94 |
47.2 |
850 |
56.94 |
47.2 |
850 |
||
48.4 |
55.6 |
1000 |
48.4 |
55.6 |
1000 |
||
38.41 |
70 |
1260 |
38.41 |
70 |
1260 |
||
35.59 |
75.66 |
1360 |
35.59 |
75.66 |
1360 |
||
30.25 |
88.9 |
1600 |
30.25 |
88.9 |
1600 |
||
27.5 |
97.8 |
1760 |
27.5 |
97.8 |
1760 |
||
24.2 |
111.1 |
2000 |
24.2 |
111.1 |
2000 |
||
22 |
122.2 |
2200 |
22 |
122.2 |
2200 |
||
20.17 |
133.3 |
2400 |
20.17 |
133.3 |
2400 |
||
18.62 |
144.4 |
2600 |
18.62 |
144.4 |
2600 |
||
17.29 |
155.6 |
2800 |
|
||||
16.13 |
166.7 |
3000 |
|
|
|
The difference between single conductor heating cable and double conductor heating cable :
1, for single conductor heating cable and double conductor heating cable is, some differences in the intensity of electromagnetic radiation, double guide than a single lead electromagnetic radiation intensity low, but are in the countries and the requirements of relevant standards within, and the better the quality of the heating cable both single channel heating cable or double guide heating cable his electromagnetic radiation is far lower than the national standards and related, generally only the provisions of the state value of tens of or hundreds of.
2, then is the construction requirements are different, because of the single conductor heating cable at both ends have the cold line, double guide heating cables to one end the cold line is closed, so a single conductor heating cable laying than double guide heating cable requirements;
3, then is inner joint number and the probability of failure, general double wires have three joints (here refers to is the internal metal joint is generally cold hotline the two connectors, terminal connector A, a total of three, the individual is two joints), and single channel heating cable only two cold hotline joint, double guide heating cable joint number than single channel heating cable is more, theory of double guide heating cable fault probability is slightly higher than that of single channel heating cable;
In addition to the two kinds of external heating effect of heating cable above points without any difference. From the described above we can draw the conclusion:
1, biderivation heating cable electromagnetic radiation is less than single channel heating cable, but are less than in the standard, no harm.
2, single conductor heating cable joint number than the general double condcutor heating cable less one small failure probability theory 33%.
Choose a single conductor heating cable or double heating cable to see your starting point, in meeting the national standard on the basis of all have no problem, you can choose after comprehensive comparison.
Take a simple example: everyone is using a mobile phone, then you say good or flip straight well? Choose a clamshell or straight, then models at different prices are different, you say they have a difference? Obviously there is some, but can be used and are very good, look at the price, or someone to buy expensive this is not wrong.
Application of electric heating cable :
Electric Heating Cable Laying structure:
Extruded sheet, reflective film, steel nets, heating cable, temperature controller, temperature sensing device.
Construction:
A, check the laying area to confirm its compliance with the construction conditions.
B, clean up the laying area.
C, laying the insulation layer (laying only in the bottom layer)
D, laying reflective layer
E, laying steel mesh.
F, according to the design drawings of the laying of heating cable.
G, standard resistance and insulation resistance of heating cable.
H, according to the design requirements of the laying of the thermal storage layer of cement mortar, as a moisture barrier layer, laying the ground decoration materials, complete the construction of the ground.
I, installation thermostat.
Factory showing:
Compared with the traditional method of heating, electric heating has the following advantages:
First of all, the room temperature distribution is uniform. Floor heating method, because it is the entire floor of the heat, so the temperature of the room is very small. And the indoor temperature is a bottom-up gradually decreased and the ground temperature is higher than that of the human respiratory system temperature, give a person with the first cold feet warm and comfortable feeling.
Second, it is conducive to create a healthy indoor environment. The heat sink is used for heating, the general water temperature is above 7 degrees Celsius, but when the temperature reaches 8 degrees, the dust group is generated, and the wall above the heating is covered with dust. And floor heating can remove the dust group and the turbid air convection, giving a fresh, warm and healthy environment.
Third, high efficiency and energy saving. Because of the radiant surface of the heating, the relative demand of the water supply temperature is low, only 4 to 5 degrees. And can overcome the traditional heating part of the heat.
Heating cable also can use for outdoor melting snow:
Related Products: Heating cable mat, Self regulating heating cable
Our Services
Packaging & Shipping
Certification: